Energy efficiency and maintenance

Minimises electricity consumption by up to 60% compared to the competition. With sequential heating, melting efficiency is ensured by homogeneous temperature distribution and adhesive protection.

Energy efficiency and maintenance
Connectivity for your everyday life

Connectivity for your everyday life

With multiple connectivity options via remote control from any device, features numerous communication protocols.

Take a step forward with data monitoring knowing the status of the equipment at all times, being able to carry out remote maintenance

Flexibility: the melter that adapts to you

Advanced usability thanks to a control panel with an easy to use 7” touchscreen interface. With configurable outputs, we provide maximum operator safety thanks to the removable HMI screen, allowing the control to be operated from a remote location.

The cool-touch housings guarantee maximum operator safety due to simplified loading and cleaning. Total accessibility with low maintenance costs.

Flexibility: the melter that adapts to you
Easy integration

Easy integration

Fully integrated into the main machine, all equipment can be controlled from a single interface thanks to an online interconnection.

WHERE TECH MEETS MAGIC BENEFITS THAT CHANGE EVERYTHING

WIFI connection

WIFI connection

Wide variety of communication protocols

Wide variety of communication protocols

High-tech within everyone's reach

High-tech within everyone's reach

Ease of use and installation

Ease of use and installation

Boost your productivity with its versatility

Boost your productivity with its versatility

Energy efficiency

Energy efficiency

Specifications that change everything

Meet the melter that changes your production processes to make them more efficient and faster.

TECHNICAL SPECIFICATIONS

Micron+ 5

  • MELTING CAPACITY
    de 9.0 a 30kg/h
  • PUMPING CAPACITY
    • SIMPLE PUMP: 1, 2.5, 4, 8 cc/rev
    • DOUBLE PUMP: 2×0.93, 2×1.86, 2×3.71, 2×4.8 cc/rev
  • NUMBER OF OUTLETS
    2, 4 or 6 electrical outlets – 2 0 four with two pumps.
  • TEMPERATURE RANGE
    0 a 200°C (32 a 392° F)
  • TEMPERATURE CONTROL
    Pt100, Ni120 o NTC-R
  • MAXIMUM WORKING PRESSURE
    90 bar (1.305 psi)
  • MAXIMUM POWER TO BE INSTALLED
    • 1 single pump/ 2 outputs 1 x 6.9KW/ 3 x 3.0KW
    • 1 single pump / 4 outlets 1 x 10.5KW/ 3 x 4.0KW
    • 1 single pump / 6 outlets 1 x 14.2KW/ 3 x 5.8KW
    • 2 single pumps / 2 outputs 1 x 8.3KW/ 3 x 3.3KW
    • 2 single pumps / 4 outputs 1 x 11.9KW/ 3 x 4.6KW
  • ELECTRICAL FUNCTIONALITIES
    • INPUTS: Equipment On-Off, Standby, activity control (auto Standby/OFF), pumping On-Off, communications On-Off, electrical output inhibition, trip inhibition.
    • OUTPUTS: Low level adhesive, pump on, temperature ok / standby on / alarms on / machine ready / adhesive level (na).
  • ELECTRICAL REQUIREMENTS
    1N ~ 230V 50/60Hz + PE ó 3N ~ 400V 50/60Hz + PE. / 3~ 230 V 50/60 hz + PE

Micron+ 10

  • MELTING CAPACITY
    13.5 kg/h
  • PUMPING CAPACITY
    • SIMPLE PUMP: 1, 2.5, 4, 8 cc/rev
    • DOUBLE PUMP: 2×0.93, 2×1.86, 2×3.71, 2×4.8 cc/rev
  • NUMBER OF OUTLETS
    2, 4 or 6 electrical outlets – 2 0 four with two pumps.
  • TEMPERATURE RANGE
    0 to 200°C (32 to 392°F).
  • CONTROL DE TEMPERATURA
    Pt100, Ni120 or NTC
  • TEMPERATURE CONTROL
    90 bar (1.305 psi)
  • MAXIMUM WORKING PRESSURE
    • 1 single pump/ 2 outputs 1 x 6.9KW/ 3 x 3.0KW
    • 1 single pump / 4 outlets 1 x 10.5KW/ 3 x 4.0KW
    • 1 single pump / 6 outlets 1 x 15.2KW/ 3 x 5.8KW
    • 2 single pumps / 2 outputs 1 x 9.3KW/ 3 x 4.0KW
    • 2 bombas simples / 4 salidas 1 x 11,9KW/ 3 x 4,6KW
  • ELECTRICAL FUNCTIONALITIES
    • INPUTS: Equipment On-Off, Standby, activity control (auto Standby/OFF), pumping On-Off, communications On-Off, electrical output inhibition, trip inhibition.
    • OUTPUTS: Low level adhesive, pump on, temperature ok / standby on / alarms on / machine ready / adhesive level (na).
  • ELECTRICAL REQUIREMENTS
    1N ~ 230V 50/60Hz + PE ó 3N ~ 400V 50/60Hz + PE. / 3~ 230 V 50/60 hz + PE

Micron+ 20

  • MELTING CAPACITY
    19 kg/h
  • PUMPING CAPACITY
    • SIMPLE PUMP: 1, 2.5, 4, 8 cc/rev
    • DOUBLE PUMP: 2×0.93, 2×1.86, 2×3.71, 2×4.8 cc/rev
  • NUMBER OF OUTLETS
    2, 4 or 6 electrical outlets – 2 0 four with two pumps.
  • TEMPERATURE RANGE
    0 to 200°C (32 to 392°F).
  • TEMPERATURE CONTROL
    Pt100, Ni120 or NTC
  • MAXIMUM WORKING PRESSURE
    90 bar (1.305 psi)
  • MAXIMUM POWER TO BE INSTALLED
    • 1 single pump/ 2 outputs 1 x 8.5KW/ 3 x 4.5KW
    • 1 single pump / 4 outlets 1 x 12.1KW/ 3 x 4.5KW
    • 1 single pump / 6 outlets 1 x 15.6KW/ 3 x 5.8KW
    • 2 single pumps / 2 outputs 1 x 9.8KW/ 3 x 4.5KW
    • 2 single pumps / 4 outputs 1 x 13KW/ 3 x 4.6KW
  • ELECTRICAL FUNCTIONALITIES
    • ENTRADAS: On-Off equipo, Standby, control de actividad (auto Standby/OFF), On-Off bombeo, On-Off comunicaciones, inhibición de salidas eléctrica, inhibición de disparos.
    • OUTPUTS: Low level adhesive, pump on, temperature ok / standby on / alarms on / machine ready / adhesive level (na).
  • ELECTRICAL REQUIREMENTS
    1N ~ 230V 50/60Hz + PE ó 3N ~ 400V 50/60Hz + PE. / 3~ 230 V 50/60 hz + PE

Micron+ 35

  • MELTING CAPACITY
    30 kg/h
  • PUMPING CAPACITY
    • SIMPLE PUMP: 1, 2.5, 4, 8 cc/rev
    • DOUBLE PUMP: 2×0.93, 2×1.86, 2×3.71, 2×4.8 cc/rev
  • NUMBER OF OUTLETS
    2, 4 or 6 electrical outlets – 2 0 four with two pumps.
  • TEMPERATURE RANGE
    0 to 200°C (32 to 392°F).
  • TEMPERATURE CONTROL
    Pt100, Ni120 or NTC
  • MAXIMUM WORKING PRESSURE
    90 bar (1.305 psi)
  • MAXIMUM POWER TO BE INSTALLED
    • 1 single pump/ 2 outputs 1 x 10KW/ 3 x 4.3KW
    • 1 single pump / 4 outlets 1 x 13.5KW/ 3 x 6.1KW
    • 1 single pump / 6 outlets 1 x 17.2KW/ 3 x 7.9KW
    • 2 single pumps / 2 outputs 1 x 11.3KW/ 3 x 5.3KW
    • 2 single pumps / 4 outputs 1 x 14.9KW/ 3 x 7.1KW
  • ELECTRICAL FUNCTIONALITIES
    • INPUTS: Equipment On-Off, Standby, activity control (auto Standby/OFF), pumping On-Off, communications On-Off, electrical output inhibition, trip inhibition
    • OUTPUTS: Low level adhesive, pump on, temperature ok / standby on / alarms on / machine ready / adhesive level (na).
  • ELECTRICAL REQUIREMENTS
    1N ~ 230V 50/60Hz + PE ó 3N ~ 400V 50/60Hz + PE. / 3~ 230 V 50/60 hz + PE
Fieldbus Configuration Software

Accesories

We put Meler’s know-how at the service of your project, regardless of your industry sector. That’s why in our product range you can also find accessories to increase the production capacity of your business.

Related Products